Beschreibung
Flange dimensions: 100 mm
Rated Output Power: 1000 – 2000 W
Rated Torque: 3,18 – 6,37 Nm
Rated Speed: 3000 rpm
Loggen Sie sich ein, um Preise für dieses Produkt zu sehen
inkl. 19 % MwSt.
Flange dimensions: 100 mm
Rated Output Power: 1000 – 2000 W
Rated Torque: 3,18 – 6,37 Nm
Rated Speed: 3000 rpm
Flange dimensions: 100 mm
Rated Output Power: 1000 – 2000 W
Rated Torque: 3,18 – 6,37 Nm
Rated Speed: 3000 rpm
Specification | TC-E 100 4B D5 2 |
---|---|
Continuous Stall Torque | 6.37 Nm |
Peak Torque | 19.11 Nm |
Nominal working Speed | 3000 rpm |
Maximum working speed | 6000 rpm |
Nominal Torque | 6.37 Nm |
Nominal Current | 10.27 Arms |
Nominal Power | 2 kW |
Rated winding voltage | 230 Vac |
Maximum winding voltage | 360 Vdc |
Maximum voltage to ground | 255 Vac |
Maximum current | 35 Arms |
Continuous Stall current | 9.87 Arms |
Voltage Constant | 39 Vrms/Krpm |
Torque Constant | 0.65 Nm/Arms |
Winding resistance | 0.36 Ω |
Winding inductance qu-v | 2.6 mH |
Winding inductance du-v | 2.59 mH |
Rotor inertia without holding brake | 4.27 kg·cm² |
Rotor inertia with holding brake | 4.34 kg·cm² |
Mass without holding brake | 6.7 Kg |
Mass with holding brake | 7.2 Kg |
Thermal time constant | 30 min |
Maximum radial shaft load | 570 N |
Maximum axial shaft load | 155 N |
Family Specification | TC-E 100 4B D5 2 |
---|---|
Time Rating | Continuous |
Insulation Class | F |
Enclosure | Totally enclosed. Self-cooled |
Protection Class | IP 54 Standard IP 65 with shaft sealing |
Ambient Temperature | -20 to 40 °C |
Ambient Humidity | 5 to 85% (non-condensing) % |
Poles | 10 |
Certification | UL 1004, CSA, CE, RoHS, Reach compliance |
Recommendation | Rated output with 300x300x20mm steel heat sink flange coupling – Ambient temperature 40°C – Derating must be considered if the oil seal is applied |
Family Overview | TC-E 100 4B D5 2 |
---|---|
Flange dimensions | 100 mm |
Rated Output Power | 1000 – 2000 Watt |
Rated Torque | 3,18 – 6,37 Nm |
Rated Speed | 3000 rpm |
Technische Angaben dienen als Orientierungswerte, da die einzelnen Antriebe und Motoren anwendungsbezogen konfiguriert werden. Technische und optische Änderungen vorbehalten.