MCode OS program storage |
Type Flash |
MCode OS program storage |
11,120 Bytes |
User registers (Integer) |
4 |
User registers (Floating point) |
8 |
User registers Length |
32 bits |
Math |
+, -, x, ÷, >, <, =, <=, >= |
Logic |
AND, OR, XOR, NOT |
Trigonometric |
ABS, COS, ACOS, LOG2, LOG10, PI, SIN, ASIN, SQRT, TAN, ATAN |
Branch functions |
Branch & call |
Input functions |
Home, limit plus, limit minus, go, stop, pause, jog plus, jog minus, general purpose, capture |
Output functions |
Moving, error, velocity change, stall, locked rotor, moving position, hMT active, make-up active, encoder A, encoder B, trip, attention. general purpose, |
Trip functions |
Trip on input, trip on position, trip on time, trip capture, trip on relative position, trip on main power loss |
Encoder functions1 |
hMTechnology, stall detection, position maintenance, find index |
EtherNet/IP (ODVA Confomance Checked) Object model |
Identity object 0x01 |
EtherNet/IP (ODVA Confomance Checked) Object model |
Assembly object (parameters mappable) 0x04 |
EtherNet/IP (ODVA Confomance Checked) Object model |
TCP object 0xF5 |
EtherNet/IP (ODVA Confomance Checked) Object model |
Ethernet object 0xF6 |
EtherNet/IP Manufacturer specific object classes |
Setup instructions 0x64 |
EtherNet/IP Manufacturer specific object classes |
Miscellaneous instructions and flags 0x65 |
EtherNet/IP Manufacturer specific object classes |
Motion instructions and flags 0x66 |
EtherNet/IP Manufacturer specific object classes |
I/O instruction variables and flags 0x67 |
EtherNet/IP Manufacturer specific object classes |
Position related instructions and flags 0x68 |
EtherNet/IP Manufacturer specific object classes |
Encoder related instructions and flags1 0x69 |
EtherNet/IP Manufacturer specific object classes |
hMTechnology specific instructions1 0x6A |
Modbus/TCP Device ID |
Read device identification 43/14d (0x2B/0x0E) |
Modbus/TCP Public function codes |
Read digital inputs 02d (0x02) |
Modbus/TCP Public function codes |
Read coils (digital outputs) 01d (0x01) |
Modbus/TCP Public function codes |
Write single coil (digital output) 05d (0x05) |
Modbus/TCP Public function codes |
Read holding register 03d (0x03) |
Modbus/TCP Public function codes |
Write multiple registers 16d (0x10) |
Modbus/TCP Manufacturer specific function codes |
Read I/O and trip configuration and parameters 65d (0x41) |
Modbus/TCP Manufacturer specific function codes |
Write I/O and trip configuration and parameters, enter upgrade mode. 66d (0x42) |
Modbus/TCP Profinet IO |
Slot 1 Output |
Modbus/TCP Profinet IO |
128 Bytes Size |
Modbus/TCP Profinet IO |
38 Registers |
Modbus/TCP Profinet IO |
Slot 2 Input |
Modbus/TCP Profinet IO |
34 Registers |
Modbus/TCP Profinet IO |
Variable, user defined Register mapping |