MCode OS program storage | | Type Flash |
MCode OS program storage | | 11,120 Bytes |
User registers (Integer) | | 4 |
User registers (Floating point) | | 8 |
User registers Length | | 32 bits |
Math | | +, -, x, ÷, >, <, =, <=, >= |
Logic | | AND, OR, XOR, NOT |
Trigonometric | | ABS, COS, ACOS, LOG2, LOG10, PI, SIN, ASIN, SQRT, TAN, ATAN |
Branch functions | | Branch & call |
Input functions | | Home, limit plus, limit minus, go, stop, pause, jog plus, jog minus, general purpose, capture |
Output functions | | Moving, error, velocity change, stall, locked rotor, moving position, hMT active, make-up active, encoder A, encoder B, trip, attention. general purpose, |
Trip functions | | Trip on input, trip on position, trip on time, trip capture, trip on relative position, trip on main power loss |
Encoder functions1 | | hMTechnology, stall detection, position maintenance, find index |
EtherNet/IP (ODVA Confomance Checked) Object model | 0x01 | Identity object |
EtherNet/IP (ODVA Confomance Checked) Object model | 0x04 | Assembly object (parameters mappable) |
EtherNet/IP (ODVA Confomance Checked) Object model | 0xF5 | TCP object |
EtherNet/IP (ODVA Confomance Checked) Object model | 0xF6 | Ethernet object |
EtherNet/IP Manufacturer specific object classes | 0x64 | Setup instructions |
EtherNet/IP Manufacturer specific object classes | 0x65 | Miscellaneous instructions and flags |
EtherNet/IP Manufacturer specific object classes | 0x66 | Motion instructions and flags |
EtherNet/IP Manufacturer specific object classes | 0x67 | I/O instruction variables and flags |
EtherNet/IP Manufacturer specific object classes | 0x68 | Position related instructions and flags |
EtherNet/IP Manufacturer specific object classes | 0x69 | Encoder related instructions and flags1 |
EtherNet/IP Manufacturer specific object classes | 0x6A | hMTechnology specific instructions1 |
Modbus/TCP Device ID | 43/14d (0x2B/0x0E) | Read device identification |
Modbus/TCP Public function codes | 02d (0x02) | Read digital inputs |
Modbus/TCP Public function codes | 01d (0x01) | Read coils (digital outputs) |
Modbus/TCP Public function codes | 05d (0x05) | Write single coil (digital output) |
Modbus/TCP Public function codes | 03d (0x03) | Read holding register |
Modbus/TCP Public function codes | 16d (0x10) | Write multiple registers |
Modbus/TCP Manufacturer specific function codes | 65d (0x41) | Read I/O and trip configuration and parameters |
Modbus/TCP Manufacturer specific function codes | 66d (0x42) | Write I/O and trip configuration and parameters, enter upgrade mode. |
Modbus/TCP Profinet IO | Output | Slot 1 |
Modbus/TCP Profinet IO | Size | 128 Bytes |
Modbus/TCP Profinet IO | Registers | 38 |
Modbus/TCP Profinet IO | Input | Slot 2 |
Modbus/TCP Profinet IO | Registers | 34 |
Modbus/TCP Profinet IO | Register mapping | Variable, user defined |