| Parameter | Unit | TC-E 100 4A D1 2 | TC-E 100 4B D5 2 | TC-E 100 4A D6 4 | TC-E 100 4B H3 4 |
|---|---|---|---|---|---|
| Continous stall torque | Nm | 3.18 | 6.37 | 3.18 | – |
| Maximum voltage to ground | Vac | 255 | 255 | 265 | – |
| Maximum current | Arms | 20 | 35 | 16.4 | – |
| Continuous stall current | Arms | 5.83 | 9.87 | 5.06 | – |
| Voltage constant | Vrms/Krpm | 33 | 39 | 38 | – |
| Torque Constant | Nm/Arms | 0.55 | 0.65 | 0.63 | – |
| Winding resistance | Ω | 0.67 | 0.36 | 0.89 | – |
| Winding inductance qu-v | mH | 4.3 | 2.6 | 5.7 | – |
| Winding inductance du-v | mH | 4.2 | 2.59 | 5.6 | – |
| Rotor inertia without holding brake | kg·cm² | 2.39 | 4.27 | 2.39 | – |
| Rotor inertia with holding brake | kg·cm² | 2.44 | 4.34 | 2.44 | – |
| Peak Torque | Nm | 9.54 | 19.11 | 9.54 | – |
| Mass without holding brake | Kg | 4.6 | 6.7 | 4.6 | – |
| Mass with holding brake | Kg | 5.1 | 7.2 | 5.1 | – |
| Thermal time constant | min | 28 | 30 | 28 | – |
| Maximum radial shaft load | N | 570 | 570 | 570 | – |
| Maximum axial shaft load | N | 155 | 155 | 155 | – |
| Nominal speed | rpm | 3000 | 3000 | 3000 | – |
| Maximum working speed | rpm | 6000 | 6000 | 6000 | – |
| Nominal torque | Nm | 3.18 | 6.37 | 3.18 | – |
| Nominal current | Arms | 6.64 | 10.27 | 5.77 | – |
| Nominal power | kW | 1 | 2 | 1 | – |
| Rated winding voltage | Vac | 230 | 230 | 400 | – |
| Maximum winding voltage | Vdc | 360 | 360 | 650 | – |
| Family Specification | Unit | TC-E 100 |
|---|---|---|
| Time Rating | Continuous | |
| Insulation Class | F | |
| Enclosure | Totally enclosed. Self-cooled | |
| Protection Class | IP 54 Standard IP 65 with shaft sealing | |
| Ambient Temperature | °C | -20 to 40 |
| Ambient Humidity | % | 5 to 85% (non-condensing) |
| Poles | 10 | |
| Certification | UL 1004, CSA, CE, RoHS, Reach compliance | |
| Recommendation | Rated output with 300x300x20mm steel heat sink flange coupling – Ambient temperature 40°C – Derating must be considered if the oil seal is applied |
| Family Overview | Unit | TC-E 100 |
|---|---|---|
| Flange dimensions | mm | 100 |
| Rated Output Power | Watt | 1000 – 2000 |
| Rated Torque | Nm | 3,18 – 6,37 |
| Rated Speed | rpm | 3000 |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
| Parameter | Unit | TC-E 100 4A D1 2 |
|---|---|---|
| Continous stall torque | Nm | 3.18 |
| Maximum voltage to ground | Vac | 255 |
| Maximum current | Arms | 20 |
| Continuous stall current | Arms | 5.83 |
| Voltage constant | Vrms/Krpm | 33 |
| Torque Constant | Nm/Arms | 0.55 |
| Winding resistance | Ω | 0.67 |
| Winding inductance qu-v | mH | 4.3 |
| Winding inductance du-v | mH | 4.2 |
| Rotor inertia without holding brake | kg·cm² | 2.39 |
| Rotor inertia with holding brake | kg·cm² | 2.44 |
| Peak Torque | Nm | 9.54 |
| Mass without holding brake | Kg | 4.6 |
| Mass with holding brake | Kg | 5.1 |
| Thermal time constant | min | 28 |
| Maximum radial shaft load | N | 570 |
| Maximum axial shaft load | N | 155 |
| Nominal speed | rpm | 3000 |
| Maximum working speed | rpm | 6000 |
| Nominal torque | Nm | 3.18 |
| Nominal current | Arms | 6.64 |
| Nominal power | kW | 1 |
| Rated winding voltage | Vac | 230 |
| Maximum winding voltage | Vdc | 360 |
| Family Specification | Unit | TC-E 100 4A D1 2 |
|---|---|---|
| Time Rating | Continuous | |
| Insulation Class | F | |
| Enclosure | Totally enclosed. Self-cooled | |
| Protection Class | IP 54 Standard IP 65 with shaft sealing | |
| Ambient Temperature | °C | -20 to 40 |
| Ambient Humidity | % | 5 to 85% (non-condensing) |
| Poles | 10 | |
| Certification | UL 1004, CSA, CE, RoHS, Reach compliance | |
| Recommendation | Rated output with 300x300x20mm steel heat sink flange coupling – Ambient temperature 40°C – Derating must be considered if the oil seal is applied |
| Family Overview | Unit | TC-E 100 4A D1 2 |
|---|---|---|
| Flange dimensions | mm | 100 |
| Rated Output Power | Watt | 1000 – 2000 |
| Rated Torque | Nm | 3,18 – 6,37 |
| Rated Speed | rpm | 3000 |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
| Parameter | Unit | TC-E 100 4B D5 2 |
|---|---|---|
| Continous stall torque | Nm | 6.37 |
| Maximum voltage to ground | Vac | 255 |
| Maximum current | Arms | 35 |
| Continuous stall current | Arms | 9.87 |
| Voltage constant | Vrms/Krpm | 39 |
| Torque Constant | Nm/Arms | 0.65 |
| Winding resistance | Ω | 0.36 |
| Winding inductance qu-v | mH | 2.6 |
| Winding inductance du-v | mH | 2.59 |
| Rotor inertia without holding brake | kg·cm² | 4.27 |
| Rotor inertia with holding brake | kg·cm² | 4.34 |
| Peak Torque | Nm | 19.11 |
| Mass without holding brake | Kg | 6.7 |
| Mass with holding brake | Kg | 7.2 |
| Thermal time constant | min | 30 |
| Maximum radial shaft load | N | 570 |
| Maximum axial shaft load | N | 155 |
| Nominal speed | rpm | 3000 |
| Maximum working speed | rpm | 6000 |
| Nominal torque | Nm | 6.37 |
| Nominal current | Arms | 10.27 |
| Nominal power | kW | 2 |
| Rated winding voltage | Vac | 230 |
| Maximum winding voltage | Vdc | 360 |
| Family Specification | Unit | TC-E 100 4B D5 2 |
|---|---|---|
| Time Rating | Continuous | |
| Insulation Class | F | |
| Enclosure | Totally enclosed. Self-cooled | |
| Protection Class | IP 54 Standard IP 65 with shaft sealing | |
| Ambient Temperature | °C | -20 to 40 |
| Ambient Humidity | % | 5 to 85% (non-condensing) |
| Poles | 10 | |
| Certification | UL 1004, CSA, CE, RoHS, Reach compliance | |
| Recommendation | Rated output with 300x300x20mm steel heat sink flange coupling – Ambient temperature 40°C – Derating must be considered if the oil seal is applied |
| Family Overview | Unit | TC-E 100 4B D5 2 |
|---|---|---|
| Flange dimensions | mm | 100 |
| Rated Output Power | Watt | 1000 – 2000 |
| Rated Torque | Nm | 3,18 – 6,37 |
| Rated Speed | rpm | 3000 |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
| Parameter | Unit | TC-E 100 4A D6 4 |
|---|---|---|
| Continous stall torque | Nm | 3.18 |
| Maximum voltage to ground | Vac | 265 |
| Maximum current | Arms | 16.4 |
| Continuous stall current | Arms | 5.06 |
| Voltage constant | Vrms/Krpm | 38 |
| Torque Constant | Nm/Arms | 0.63 |
| Winding resistance | Ω | 0.89 |
| Winding inductance qu-v | mH | 5.7 |
| Winding inductance du-v | mH | 5.6 |
| Rotor inertia without holding brake | kg·cm² | 2.39 |
| Rotor inertia with holding brake | kg·cm² | 2.44 |
| Peak Torque | Nm | 9.54 |
| Mass without holding brake | Kg | 4.6 |
| Mass with holding brake | Kg | 5.1 |
| Thermal time constant | min | 28 |
| Maximum radial shaft load | N | 570 |
| Maximum axial shaft load | N | 155 |
| Nominal speed | rpm | 3000 |
| Maximum working speed | rpm | 6000 |
| Nominal torque | Nm | 3.18 |
| Nominal current | Arms | 5.77 |
| Nominal power | kW | 1 |
| Rated winding voltage | Vac | 400 |
| Maximum winding voltage | Vdc | 650 |
| Family Specification | Unit | TC-E 100 4A D6 4 |
|---|---|---|
| Time Rating | Continuous | |
| Insulation Class | F | |
| Enclosure | Totally enclosed. Self-cooled | |
| Protection Class | IP 54 Standard IP 65 with shaft sealing | |
| Ambient Temperature | °C | -20 to 40 |
| Ambient Humidity | % | 5 to 85% (non-condensing) |
| Poles | 10 | |
| Certification | UL 1004, CSA, CE, RoHS, Reach compliance | |
| Recommendation | Rated output with 300x300x20mm steel heat sink flange coupling – Ambient temperature 40°C – Derating must be considered if the oil seal is applied |
| Family Overview | Unit | TC-E 100 4A D6 4 |
|---|---|---|
| Flange dimensions | mm | 100 |
| Rated Output Power | Watt | 1000 – 2000 |
| Rated Torque | Nm | 3,18 – 6,37 |
| Rated Speed | rpm | 3000 |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
| Family Specification | Unit | TC-E 100 4B H3 4 |
|---|---|---|
| Time Rating | Continuous | |
| Insulation Class | F | |
| Enclosure | Totally enclosed. Self-cooled | |
| Protection Class | IP 54 Standard IP 65 with shaft sealing | |
| Ambient Temperature | °C | -20 to 40 |
| Ambient Humidity | % | 5 to 85% (non-condensing) |
| Poles | 10 | |
| Certification | UL 1004, CSA, CE, RoHS, Reach compliance | |
| Recommendation | Rated output with 300x300x20mm steel heat sink flange coupling – Ambient temperature 40°C – Derating must be considered if the oil seal is applied |
| Family Overview | Unit | TC-E 100 4B H3 4 |
|---|---|---|
| Flange dimensions | mm | 100 |
| Rated Output Power | Watt | 1000 – 2000 |
| Rated Torque | Nm | 3,18 – 6,37 |
| Rated Speed | rpm | 3000 |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.