Produkt
incl. VAT
KOCO offers wide range of Brushless DC Motor electronics for speed and position control.
From low current to Maximum 30A, KOCO provides 4 different kinds of speed controller via RS485 and Analog command.
incl. VAT
KOCO offers wide range of Brushless DC Motor electronics for speed and position control.
From low current to Maximum 30A, KOCO provides 4 different kinds of speed controller via RS485 and Analog command.
Specifications | DS-OLBS2-FRS4 | DS-OLBS4-FRS4 | DS-OLBS6-FSC | DS-OLBS8-FRS4 | DS-BVM-FCAO/FETC | DS-BVS-FCAO/FETC |
---|---|---|---|---|---|---|
Adapted Motor | Less than 80W Brushless DC motor | Less than 200W Brushless DC motor | Less than 400W Brushless DC motor | Less than 750W Brushless DC motor | Less than 750W Brushless DC motor | Less than 750W Brushless DC motor |
Power Supply | 12 – 24 | 24 – 48 | 24 – 48 | 24 – 48 | 24 – 48 | 24 – 48 |
Output Current | 5 A | 10 A | 15 A | 30 A | 30 A | 30 A |
Speed Controlled Analog Voltage | 0 – 5 | 0 – 5 | 0 – 5 | 0 – 5 | 0 – 5 | 0 – 5 |
Structure | Wall mounting | Wall mounting | Wall mounting | Wall mounting | Wall mounting | Wall mounting |
Cooling Method | Air cooling | Air cooling | Air cooling | Air cooling | Air cooling | Air cooling |
Control Signal | Full isolation of input and output signals | Full isolation of input and output signals | Full isolation of input and output signals | Full isolation of input and output signals | Full isolation of input and output signals | Full isolation of input and output signals |
Protections | Over voltage, under voltage, over current, over temperature, abnormal hall signal and other fault alarms | Over voltage, under voltage, over current, over temperature, abnormal hall signal and other fault alarms | Over voltage, under voltage, over current, over temperature, abnormal hall signal and other fault alarms | Over voltage, under voltage, over current, over temperature, abnormal hall signal and other fault alarms | Over voltage, under voltage, over current, over temperature, abnormal hall signal and other fault alarms | Over voltage, under voltage, over current, over temperature, abnormal hall signal and other fault alarms |
Communication Mode | RS-485 Multi-axes communication | RS-485 Multi-axes communication | RS-485 Multi-axes communication | RS-485 Multi-axes communication | RS-485 Multi-axes communication | RS-485 Multi-axes communication |
Operating Temperature | 0 ~ 45°C | 0 ~ 45°C | 0 ~ 45°C | 0 ~ 45°C | 0 ~ 45°C | 0 ~ 45°C |
Storage Temperature | -20 ~ 85°C | -20 ~ 85°C | -20 ~ 85°C | -20 ~ 85°C | -20 ~ 85°C | -20 ~ 85°C |
Operating Humidity | <85% RH | <85% RH | <85% RH | <85% RH | <85% RH | <85% RH |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
Specification | DS-OLBS2-FRS4 |
---|---|
Adapted Motor | Less than 80W Brushless DC motor |
Power Supply | 12 – 24 VDC |
Output Current | 5 A |
Speed Controlled Analog Voltage | 0 – 5 V |
Structure | Wall mounting |
Cooling Method | Air cooling |
Control Signal | Full isolation of input and output signals |
Protections | Over voltage, under voltage, over current, over temperature, abnormal hall signal and other fault alarms |
Communication Mode | RS-485 Multi-axes communication |
Operating Temperature | 0 ~ 45°C °C |
Storage Temperature | -20 ~ 85°C °C |
Operating Humidity | <85% RH |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
Specification | DS-OLBS4-FRS4 |
---|---|
Adapted Motor | Less than 200W Brushless DC motor |
Power Supply | 24 – 48 VDC |
Output Current | 10 A |
Speed Controlled Analog Voltage | 0 – 5 V |
Structure | Wall mounting |
Cooling Method | Air cooling |
Control Signal | Full isolation of input and output signals |
Protections | Over voltage, under voltage, over current, over temperature, abnormal hall signal and other fault alarms |
Communication Mode | RS-485 Multi-axes communication |
Operating Temperature | 0 ~ 45°C °C |
Storage Temperature | -20 ~ 85°C °C |
Operating Humidity | <85% RH |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
Specification | DS-OLBS6-FSC |
---|---|
Adapted Motor | Less than 400W Brushless DC motor |
Power Supply | 24 – 48 VDC |
Output Current | 15 A |
Speed Controlled Analog Voltage | 0 – 5 V |
Structure | Wall mounting |
Cooling Method | Air cooling |
Control Signal | Full isolation of input and output signals |
Protections | Over voltage, under voltage, over current, over temperature, abnormal hall signal and other fault alarms |
Communication Mode | RS-485 Multi-axes communication |
Operating Temperature | 0 ~ 45°C °C |
Storage Temperature | -20 ~ 85°C °C |
Operating Humidity | <85% RH |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
Specification | DS-OLBS8-FRS4 |
---|---|
Adapted Motor | Less than 750W Brushless DC motor |
Power Supply | 24 – 48 VDC |
Output Current | 30 A |
Speed Controlled Analog Voltage | 0 – 5 V |
Structure | Wall mounting |
Cooling Method | Air cooling |
Control Signal | Full isolation of input and output signals |
Protections | Over voltage, under voltage, over current, over temperature, abnormal hall signal and other fault alarms |
Communication Mode | RS-485 Multi-axes communication |
Operating Temperature | 0 ~ 45°C °C |
Storage Temperature | -20 ~ 85°C °C |
Operating Humidity | <85% RH |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.