Description
Flange dimensions: 40 mm
Rated Output Power: 50 – 100 W
Rated Torque: 0,16 – 0,32 Nm
Rated Speed: 3000 rpm
Flange dimensions: 40 mm
Rated Output Power: 50 – 100 W
Rated Torque: 0,16 – 0,32 Nm
Rated Speed: 3000 rpm
| Parameter | Unit | TC-E 40 1B C1 2 |
|---|---|---|
| Continuous Stall Torque | Nm | 0.32 |
| Maximum voltage to ground | Vac | 255 |
| Maximum current | Arms | 2.7 |
| Continuous Stall current | Arms | 0.81 |
| Voltage Constant | Vrms/Krpm | 24 |
| Torque Constant | Nm/Arms | 0.4 |
| Winding resistance | Ω | 23.4 |
| Winding inductance qu-v | mH | 21.5 |
| Winding inductance du-v | mH | 20.6 |
| Rotor inertia without holding brake | kg·cm² | 0.065 |
| Rotor inertia with holding brake | kg·cm² | 0.066 |
| Peak Torque | Nm | 0.96 |
| Mass without holding brake | Kg | 0.56 |
| Mass with holding brake | Kg | 0.77 |
| Thermal time constant | min | 15 |
| Maximum radial shaft load | N | 85 |
| Maximum axial shaft load | N | 40 |
| Nominal working Speed | rpm | 3000 |
| Maximum working speed | rpm | 6000 |
| Nominal Torque | Nm | 0.32 |
| Nominal Current | Arms | 0.89 |
| Nominal Power | kW | 0.1 |
| Rated winding voltage | Vac | 230 |
| Maximum winding voltage | Vdc | 360 |
| Family Specification | Unit | TC-E 40 1B C1 2 |
|---|---|---|
| Time Rating | Continous | |
| Insulation Class | F | |
| Enclosure | Totally enclosed. Self-cooled | |
| Protection Class | IP 54 Standard IP 65 with shaft sealing | |
| Ambient Temperature | °C | -20 to 40 |
| Ambient Humidity | 5 to 85% (non-condensing) | |
| Poles | 8 | |
| Certification | UL 1004, CSA, CE, RoHS, Reach compliance | |
| Recommendation | Rated output with 185x185x8mm aluminum heat sink flange coupling – Ambient Temperature 40°C – Derating must be considered if the oil seal is applied |
| Family Overview | Unit | TC-E 40 1B C1 2 |
|---|---|---|
| Flange dimensions | mm | 40 |
| Rated Output Power | Watt | 50 – 100 |
| Rated Torque | Nm | 0,16 – 0,32 |
| Rated Speed | rpm | 3000 |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.