Description
Flange dimensions: 80 mm
Rated Output Power: 480 – 1068 W
Rated Torque: 1,53 – 3,4 Nm
Rated Speed: 3000 rpm
Flange dimensions: 80 mm
Rated Output Power: 480 – 1068 W
Rated Torque: 1,53 – 3,4 Nm
Rated Speed: 3000 rpm
Flange dimensions: 80 mm
Rated Output Power: 480 – 1068 W
Rated Torque: 1,53 – 3,4 Nm
Rated Speed: 3000 rpm
Parameter | Unit | TC-X 80 4 17 |
---|---|---|
Continous Stall Torque (ambient temperature 0 to +40°C) | Nm | 4 |
Peak Torque (ambient temperature 0 to +40°C) | Nm | 12 |
Nominal Torque (ambient temperature 0 to +40°C) | Nm | 3.4 |
Rated Voltage (ambient temperature 0 to +40°C) | Vdc | 400 |
Nominal power (ambient temperature 0 to +40°C) | W | 1068 |
Continuous stall Current (ambient temperature 0 to +40°C) | Arms | 2.5 |
Maximun Current (ambient temperature 0 to +40°C) | Arms | 7.5 |
Nominal Current (ambient temperature 0 to +40°C) | Arms | 2.19 |
Nominal working Speed (ambient temperature 0 to +40°C) | rpm | 3000 |
Maximum working speed 230VAC (ambient temperature 0 to +40°C) | rpm | – |
Maximum working speed 400VAC (ambient temperature 0 to +40°C) | 3900 | |
Torque Constant (ambient temperature 0 to +40°C) | Nm/Arms | 1.6 |
Voltage Constant (ambient temperature 0 to +40°C) | Vrms/Krpm | 96 |
Winding resistance (ambient temperature 0 to +40°C) | Ohm | 6.5 |
Winding inductance (ambient temperature 0 to +40°C) | mH | 28.6 |
Electrical time constant (ambient temperature 0 to +40°C) | ms | 4.4 |
Thermal Resistance (ambient temperature 0 to +40°C) | °C/W | 1 |
Mechanical time constant (ambient temperature 0 to +40°C) | ms | 0.6 |
Rotor Inertia without feedback (ambient temperature 0 to +40°C) | kg·cm² | 1.58 |
Mass (ambient temperature 0 to +40°C) | Kg | 4.1 |
Maximum axial shaft load applied on the shaft’s center (ambient temperature 0 to +40°C) | N | 110 |
Maximun radial shaft load applied on the shaft’s center (ambient temperature 0 to +40°C) | N | 350 |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.