| Parameter | Unit | DS-BVM-FCAO/FETC | DS-BVS-FCAO/FETC | 
|---|---|---|---|
| Adapted Motor | DC / BLDC / PMSM / VCM | DC / BLDC / PMSM / VCM | |
| Operating Humidity | 10 ~ 90% RH | 10 ~ 90% RH | |
| Current (Torque) Control | Control periodic 24KHz | Control periodic 24KHz | |
| Velocity & Position Control | Control periodic 2KHz | Control periodic 2KHz | |
| Reference Command | USB + CANopen or EtherCAT (CoE, FoE) | USB + CANopen or EtherCAT (CoE, FoE) | |
| Auto Tuning | Automatic self-configuration and optimization of motor phasing, wires, current loop, velocity control loop. | Automatic self-configuration and optimization of motor phasing, wires, current loop, velocity control loop. | |
| User Interface | GUI : DINGS’ servo studio, Setting, Drive, Motor, Feedback, I/O, Motion | GUI : DINGS’ servo studio, Setting, Drive, Motor, Feedback, I/O, Motion | |
| Protective Functions | Under-and over-voltage, Over-current, Over-load (with PT), Drive over-temperature, Feedback sensor signal lost | Under-and over-voltage, Over-current, Over-load (with PT), Drive over-temperature, Feedback sensor signal lost | |
| Ambient temperature | °C | 0 ~ 45 | 0 ~ 45 | 
| Storage Temperature | °C | 0 ~ 70 | 0 ~ 70 | 
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
| Parameter | Unit | DS-BVM-FCAO/FETC | 
|---|---|---|
| Adapted Motor | DC / BLDC / PMSM / VCM | |
| Operating Humidity | 10 ~ 90% RH | |
| Current (Torque) Control | Control periodic 24KHz | |
| Velocity & Position Control | Control periodic 2KHz | |
| Reference Command | USB + CANopen or EtherCAT (CoE, FoE) | |
| Auto Tuning | Automatic self-configuration and optimization of motor phasing, wires, current loop, velocity control loop. | |
| User Interface | GUI : DINGS’ servo studio, Setting, Drive, Motor, Feedback, I/O, Motion | |
| Protective Functions | Under-and over-voltage, Over-current, Over-load (with PT), Drive over-temperature, Feedback sensor signal lost | |
| Ambient temperature | °C | 0 ~ 45 | 
| Storage Temperature | °C | 0 ~ 70 | 
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
| Parameter | Unit | DS-BVS-FCAO/FETC | 
|---|---|---|
| Adapted Motor | DC / BLDC / PMSM / VCM | |
| Operating Humidity | 10 ~ 90% RH | |
| Current (Torque) Control | Control periodic 24KHz | |
| Velocity & Position Control | Control periodic 2KHz | |
| Reference Command | USB + CANopen or EtherCAT (CoE, FoE) | |
| Auto Tuning | Automatic self-configuration and optimization of motor phasing, wires, current loop, velocity control loop. | |
| User Interface | GUI : DINGS’ servo studio, Setting, Drive, Motor, Feedback, I/O, Motion | |
| Protective Functions | Under-and over-voltage, Over-current, Over-load (with PT), Drive over-temperature, Feedback sensor signal lost | |
| Ambient temperature | °C | 0 ~ 45 | 
| Storage Temperature | °C | 0 ~ 70 | 
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.