| Parameter | Unit | SKA DDR 090.30.2.17 | SKA DDR 090.30.2.18 | SKA DDR 090.30.2.19 | SKA DDR 090.30.2.50 |
|---|---|---|---|---|---|
| Stall torque | Nm | 2 | 2 | 2 | 2 |
| Phase/phase inductance | mH | 21 | 48 | 140 | 250 |
| Electrical time constant | msec | 2.3 | 2.3 | 2.4 | 2 |
| Thermal resistance | °C/W | 3.2 | 3.2 | 3.2 | 3.2 |
| Peak torque | Nm | 15.9 | 15.9 | 14.3 | 10.5 |
| Stall current | Arms | 1.25 | 0.83 | 0.5 | 0.36 |
| Peak current | Arms | 14 | 9.3 | 4.8 | 2.1 |
| Maximum speed @230 Vac 3phase | rpm | 1200 | 1200 | 750 | 500 |
| Maximum speed @400 Vac 3phase | rpm | – | – | 1200 | 800 |
| Torque constant ± 5% | Nm/Arms | 1.14 | 1.71 | 3 | 5 |
| Voltage constant ± 5% | Vrms/krpm | 96 | 144 | 240 | 340 |
| Phase/phase resistance ± 5% | Ω | 9.7 | 22.6 | 60 | 130 |
| Family Specification | Unit | SKA DDR 090 30 |
|---|---|---|
| Time Rating | Continous | |
| Insulation Class | F | |
| Poles | 14 | |
| Insulation System UL/CSA | cURus, DV155JFile nr.:E216686 | |
| Ambient temperature | °C | 0 to 40 °C |
| Ambient humidity | 20 to 80 %RH (non condensing) | |
| Thermal protection | PT 1000 | |
| CE | certified |
| Family Overview | Unit | SKA DDR 090 30 |
|---|---|---|
| Stall Torque | Nm | 2 |
| Peak Torque | Nm | 10,5 – 15,9 |
| Maxium Speed @ 230/400 Vac | rpm | 1200 |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
| Parameter | Unit | SKA DDR 090.30.2.17 |
|---|---|---|
| Stall torque | Nm | 2 |
| Phase/phase inductance | mH | 21 |
| Electrical time constant | msec | 2.3 |
| Thermal resistance | °C/W | 3.2 |
| Peak torque | Nm | 15.9 |
| Stall current | Arms | 1.25 |
| Peak current | Arms | 14 |
| Maximum speed @230 Vac 3phase | rpm | 1200 |
| Maximum speed @400 Vac 3phase | rpm | – |
| Torque constant ± 5% | Nm/Arms | 1.14 |
| Voltage constant ± 5% | Vrms/krpm | 96 |
| Phase/phase resistance ± 5% | Ω | 9.7 |
| Family Specification | Unit | SKA DDR 090.30.2.17 |
|---|---|---|
| Time Rating | Continous | |
| Insulation Class | F | |
| Poles | 14 | |
| Insulation System UL/CSA | cURus, DV155JFile nr.:E216686 | |
| Ambient temperature | °C | 0 to 40 °C |
| Ambient humidity | 20 to 80 %RH (non condensing) | |
| Thermal protection | PT 1000 | |
| CE | certified |
| Family Overview | Unit | SKA DDR 090.30.2.17 |
|---|---|---|
| Stall Torque | Nm | 2 |
| Peak Torque | Nm | 10,5 – 15,9 |
| Maxium Speed @ 230/400 Vac | rpm | 1200 |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
| Parameter | Unit | SKA DDR 090.30.2.18 |
|---|---|---|
| Stall torque | Nm | 2 |
| Phase/phase inductance | mH | 48 |
| Electrical time constant | msec | 2.3 |
| Thermal resistance | °C/W | 3.2 |
| Peak torque | Nm | 15.9 |
| Stall current | Arms | 0.83 |
| Peak current | Arms | 9.3 |
| Maximum speed @230 Vac 3phase | rpm | 1200 |
| Maximum speed @400 Vac 3phase | rpm | – |
| Torque constant ± 5% | Nm/Arms | 1.71 |
| Voltage constant ± 5% | Vrms/krpm | 144 |
| Phase/phase resistance ± 5% | Ω | 22.6 |
| Family Specification | Unit | SKA DDR 090.30.2.18 |
|---|---|---|
| Time Rating | Continous | |
| Insulation Class | F | |
| Poles | 14 | |
| Insulation System UL/CSA | cURus, DV155JFile nr.:E216686 | |
| Ambient temperature | °C | 0 to 40 °C |
| Ambient humidity | 20 to 80 %RH (non condensing) | |
| Thermal protection | PT 1000 | |
| CE | certified |
| Family Overview | Unit | SKA DDR 090.30.2.18 |
|---|---|---|
| Stall Torque | Nm | 2 |
| Peak Torque | Nm | 10,5 – 15,9 |
| Maxium Speed @ 230/400 Vac | rpm | 1200 |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
| Parameter | Unit | SKA DDR 090.30.2.19 |
|---|---|---|
| Stall torque | Nm | 2 |
| Phase/phase inductance | mH | 140 |
| Electrical time constant | msec | 2.4 |
| Thermal resistance | °C/W | 3.2 |
| Peak torque | Nm | 14.3 |
| Stall current | Arms | 0.5 |
| Peak current | Arms | 4.8 |
| Maximum speed @230 Vac 3phase | rpm | 750 |
| Maximum speed @400 Vac 3phase | rpm | 1200 |
| Torque constant ± 5% | Nm/Arms | 3 |
| Voltage constant ± 5% | Vrms/krpm | 240 |
| Phase/phase resistance ± 5% | Ω | 60 |
| Family Specification | Unit | SKA DDR 090.30.2.19 |
|---|---|---|
| Time Rating | Continous | |
| Insulation Class | F | |
| Poles | 14 | |
| Insulation System UL/CSA | cURus, DV155JFile nr.:E216686 | |
| Ambient temperature | °C | 0 to 40 °C |
| Ambient humidity | 20 to 80 %RH (non condensing) | |
| Thermal protection | PT 1000 | |
| CE | certified |
| Family Overview | Unit | SKA DDR 090.30.2.19 |
|---|---|---|
| Stall Torque | Nm | 2 |
| Peak Torque | Nm | 10,5 – 15,9 |
| Maxium Speed @ 230/400 Vac | rpm | 1200 |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
| Parameter | Unit | SKA DDR 090.30.2.50 |
|---|---|---|
| Stall torque | Nm | 2 |
| Phase/phase inductance | mH | 250 |
| Electrical time constant | msec | 2 |
| Thermal resistance | °C/W | 3.2 |
| Peak torque | Nm | 10.5 |
| Stall current | Arms | 0.36 |
| Peak current | Arms | 2.1 |
| Maximum speed @230 Vac 3phase | rpm | 500 |
| Maximum speed @400 Vac 3phase | rpm | 800 |
| Torque constant ± 5% | Nm/Arms | 5 |
| Voltage constant ± 5% | Vrms/krpm | 340 |
| Phase/phase resistance ± 5% | Ω | 130 |
| Family Specification | Unit | SKA DDR 090.30.2.50 |
|---|---|---|
| Time Rating | Continous | |
| Insulation Class | F | |
| Poles | 14 | |
| Insulation System UL/CSA | cURus, DV155JFile nr.:E216686 | |
| Ambient temperature | °C | 0 to 40 °C |
| Ambient humidity | 20 to 80 %RH (non condensing) | |
| Thermal protection | PT 1000 | |
| CE | certified |
| Family Overview | Unit | SKA DDR 090.30.2.50 |
|---|---|---|
| Stall Torque | Nm | 2 |
| Peak Torque | Nm | 10,5 – 15,9 |
| Maxium Speed @ 230/400 Vac | rpm | 1200 |