| Parameter | Unit | T 180 22,5 17 | T 180 35 17 | T 180 47 17 |
|---|---|---|---|---|
| Continous Stall Torque | Nm | 25 | 39 | 50 |
| Maximum working speed 230VAC | rpm | 2200 | 2200 | 2200 |
| Maximum working speed 400VAC | 3000 | 3000 | 3000 | |
| Torque Constant | Nm/Arms | 1.6 | 1.6 | 1.6 |
| Voltage Constant | Vrms/Krpm | 97 | 97 | 97 |
| Winding resistance | Ω | 0.59 | 0.29 | 0.19 |
| Winding inductance | mH | 3 | 1.9 | 1.4 |
| Electrical time constant | ms | 5.1 | 6.6 | 7.4 |
| Thermal Resistance | °C/W | 0.32 | 0.27 | 0.25 |
| Mechanical timeconstant high rotor inertia | ms | 3.3 | 2.4 | 2.1 |
| Mechanical time constant low rotor inertia | ms | 2.4 | 1.7 | 1.5 |
| Peak Torque | Nm | 63 | 95 | 130 |
| High rotor inertia (as an option) without brake and without feedback | kg·cm² | 95 | 141 | 186.7 |
| Low rotor inertia (as an option) without brake and without feedback | kg·cm² | 69.5 | 102.5 | 135.5 |
| Mass without holding brake | Kg | 27.5 | 36 | 45 |
| Mass with holding brake | Kg | 33.5 | 42 | 51 |
| Maximum axial shaft load applied on the shaft’s center | N | 510 | 510 | 510 |
| Maximun radial shaft load applied on the shaft’s center | N | 1700 | 1700 | 1700 |
| Nominal Torque | Nm | 15 | 21 | 40 |
| Rated Voltage | V | 400 | 400 | 400 |
| Nominal power | W | 4700 | 6600 | 8380 |
| Continuous stall Current | Arms | 15.6 | 24.3 | 31.2 |
| Maximun Current | Arms | 39.3 | 59.2 | 81 |
| Nominal Current | Arms | 9.8 | 13.7 | 26.2 |
| Nominal working Speed | rpm | 3000 | 3000 | 2000 |
| Family Specification | Unit | TC 180 |
|---|---|---|
| Time Rating | Continuous | |
| Certification | CE | |
| Recommendation | Rated output with 500 x 500 x 30 mm metallic heat sink flange coupling – Derating must be considered if the oil seal is applied – IP 54 standard shaft bushing | |
| Insulation Class | F | |
| Enclosure | Totally enclosed. Self-cooled | |
| Protection Class | IP 65 standard on the body | |
| Insulation System UL/CSA | cURus , DV155J File nr. : E216686 | |
| Ambient Temperature | °C | 0 to 40 |
| Ambient Humidity | % | 5 to 85% (non-condensing) |
| Poles | 6 | |
| Thermal Protection | PT 1000 |
| Family Overview | Unit | TC 180 |
|---|---|---|
| Flange dimensions | mm | 180 |
| Rated Output Power | Watt | 4700 – 8380 |
| Rated Torque | Nm | 18,0 – 40,0 |
| Rated Speed | rpm | 3000 |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
| Parameter | Unit | T 180 22,5 17 |
|---|---|---|
| Continous Stall Torque | Nm | 25 |
| Maximum working speed 230VAC | rpm | 2200 |
| Maximum working speed 400VAC | 3000 | |
| Torque Constant | Nm/Arms | 1.6 |
| Voltage Constant | Vrms/Krpm | 97 |
| Winding resistance | Ω | 0.59 |
| Winding inductance | mH | 3 |
| Electrical time constant | ms | 5.1 |
| Thermal Resistance | °C/W | 0.32 |
| Mechanical timeconstant high rotor inertia | ms | 3.3 |
| Mechanical time constant low rotor inertia | ms | 2.4 |
| Peak Torque | Nm | 63 |
| High rotor inertia (as an option) without brake and without feedback | kg·cm² | 95 |
| Low rotor inertia (as an option) without brake and without feedback | kg·cm² | 69.5 |
| Mass without holding brake | Kg | 27.5 |
| Mass with holding brake | Kg | 33.5 |
| Maximum axial shaft load applied on the shaft’s center | N | 510 |
| Maximun radial shaft load applied on the shaft’s center | N | 1700 |
| Nominal Torque | Nm | 15 |
| Rated Voltage | V | 400 |
| Nominal power | W | 4700 |
| Continuous stall Current | Arms | 15.6 |
| Maximun Current | Arms | 39.3 |
| Nominal Current | Arms | 9.8 |
| Nominal working Speed | rpm | 3000 |
| Family Specification | Unit | T 180 22,5 17 |
|---|---|---|
| Time Rating | Continuous | |
| Certification | CE | |
| Recommendation | Rated output with 500 x 500 x 30 mm metallic heat sink flange coupling – Derating must be considered if the oil seal is applied – IP 54 standard shaft bushing | |
| Insulation Class | F | |
| Enclosure | Totally enclosed. Self-cooled | |
| Protection Class | IP 65 standard on the body | |
| Insulation System UL/CSA | cURus , DV155J File nr. : E216686 | |
| Ambient Temperature | °C | 0 to 40 |
| Ambient Humidity | % | 5 to 85% (non-condensing) |
| Poles | 6 | |
| Thermal Protection | PT 1000 |
| Family Overview | Unit | T 180 22,5 17 |
|---|---|---|
| Flange dimensions | mm | 180 |
| Rated Output Power | Watt | 4700 – 8380 |
| Rated Torque | Nm | 18,0 – 40,0 |
| Rated Speed | rpm | 3000 |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
| Parameter | Unit | T 180 35 17 |
|---|---|---|
| Continous Stall Torque | Nm | 39 |
| Peak Torque | Nm | 95 |
| Nominal Torque | Nm | 21 |
| Rated Voltage | V | 400 |
| Nominal power | W | 6600 |
| Continuous stall Current | Arms | 24.3 |
| Maximun Current | Arms | 59.2 |
| Nominal Current | Arms | 13.7 |
| Nominal working Speed | rpm | 3000 |
| Maximum working speed 230VAC | rpm | 2200 |
| Maximum working speed 400VAC | 3000 | |
| Torque Constant | Nm/Arms | 1.6 |
| Voltage Constant | Vrms/Krpm | 97 |
| Winding resistance | Ω | 0.29 |
| Winding inductance | mH | 1.9 |
| Electrical time constant | ms | 6.6 |
| Thermal Resistance | °C/W | 0.27 |
| Mechanical timeconstant high rotor inertia | ms | 2.4 |
| Mechanical time constant low rotor inertia | ms | 1.7 |
| High rotor inertia (as an option) without brake and without feedback | kg·cm² | 141 |
| Low rotor inertia (as an option) without brake and without feedback | kg·cm² | 102.5 |
| Mass without holding brake | Kg | 36 |
| Mass with holding brake | Kg | 42 |
| Maximum axial shaft load applied on the shaft’s center | N | 510 |
| Maximun radial shaft load applied on the shaft’s center | N | 1700 |
| Family Specification | Unit | T 180 35 17 |
|---|---|---|
| Time Rating | Continuous | |
| Certification | CE | |
| Recommendation | Rated output with 500 x 500 x 30 mm metallic heat sink flange coupling – Derating must be considered if the oil seal is applied – IP 54 standard shaft bushing | |
| Insulation Class | F | |
| Enclosure | Totally enclosed. Self-cooled | |
| Protection Class | IP 65 standard on the body | |
| Insulation System UL/CSA | cURus , DV155J File nr. : E216686 | |
| Ambient Temperature | °C | 0 to 40 |
| Ambient Humidity | % | 5 to 85% (non-condensing) |
| Poles | 6 | |
| Thermal Protection | PT 1000 |
| Family Overview | Unit | T 180 35 17 |
|---|---|---|
| Flange dimensions | mm | 180 |
| Rated Output Power | Watt | 4700 – 8380 |
| Rated Torque | Nm | 18,0 – 40,0 |
| Rated Speed | rpm | 3000 |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
| Parameter | Unit | T 180 47 17 |
|---|---|---|
| Continous Stall Torque | Nm | 50 |
| Peak Torque | Nm | 130 |
| Nominal Torque | Nm | 40 |
| Rated Voltage | V | 400 |
| Nominal power | W | 8380 |
| Continuous stall Current | Arms | 31.2 |
| Maximun Current | Arms | 81 |
| Nominal Current | Arms | 26.2 |
| Nominal working Speed | rpm | 2000 |
| Maximum working speed 230VAC | rpm | 2200 |
| Maximum working speed 400VAC | 3000 | |
| Torque Constant | Nm/Arms | 1.6 |
| Voltage Constant | Vrms/Krpm | 97 |
| Winding resistance | Ω | 0.19 |
| Winding inductance | mH | 1.4 |
| Electrical time constant | ms | 7.4 |
| Thermal Resistance | °C/W | 0.25 |
| Mechanical timeconstant high rotor inertia | ms | 2.1 |
| Mechanical time constant low rotor inertia | ms | 1.5 |
| High rotor inertia (as an option) without brake and without feedback | kg·cm² | 186.7 |
| Low rotor inertia (as an option) without brake and without feedback | kg·cm² | 135.5 |
| Mass without holding brake | Kg | 45 |
| Mass with holding brake | Kg | 51 |
| Maximum axial shaft load applied on the shaft’s center | N | 510 |
| Maximun radial shaft load applied on the shaft’s center | N | 1700 |
| Family Specification | Unit | T 180 47 17 |
|---|---|---|
| Time Rating | Continuous | |
| Certification | CE | |
| Recommendation | Rated output with 500 x 500 x 30 mm metallic heat sink flange coupling – Derating must be considered if the oil seal is applied – IP 54 standard shaft bushing | |
| Insulation Class | F | |
| Enclosure | Totally enclosed. Self-cooled | |
| Protection Class | IP 65 standard on the body | |
| Insulation System UL/CSA | cURus , DV155J File nr. : E216686 | |
| Ambient Temperature | °C | 0 to 40 |
| Ambient Humidity | % | 5 to 85% (non-condensing) |
| Poles | 6 | |
| Thermal Protection | PT 1000 |
| Family Overview | Unit | T 180 47 17 |
|---|---|---|
| Flange dimensions | mm | 180 |
| Rated Output Power | Watt | 4700 – 8380 |
| Rated Torque | Nm | 18,0 – 40,0 |
| Rated Speed | rpm | 3000 |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.