Control type |
Ethernet TCP/IP |
Communications interface |
Ethernet TCP/IP |
Communications features |
EtherNet/IP, Modbus/TCP, Profinet I/O, MCode OS |
NEMA size |
17 (42×42 mm) |
Torque range |
0.31 … 0.62 Nm |
Temperature heatsink (short-time) |
max. 85 °C |
IP rating |
IP20 |
Input voltage |
+12 to +48 +VDC |
Power supply current requirement |
2.0 A |
Aux-logic supply voltage |
12 … 24 +VDC |
Aux-Logic Supply Current |
194 mA max |
I/O functions |
Programmable I/Os |
Signal input voltage range |
5 … 24 +VDC |
Signal input current |
8.7 mA @ +5 VDC |
Signal input current |
14.6 mA @ +24 VDC |
Signal input frequency |
5 kHz |
Signal input isolation |
Galvanic |
Signal input protection class |
III |
Signal output current |
1 … 5.5 mA |
Signal output voltage open-collector |
60 +VDC |
Signal output voltage open-emitter |
7 +VDC |
Signal output current open-collector |
5.5 mA |
Signal output current open-emitter |
5.5 mA |
Signal output isolation |
Galvanic |
Analog input availability |
Not available on LMD models with absolute encoder |
Analog input voltage mode |
0 … 5 0 … 5 VDC |
Analog input voltage mode |
0 … 10 0 … 10 VDC |
Analog input current loop mode |
0 … 20 mA |
Analog input resolution |
12 Bits |
Analog input isolation |
None |
Microstep resolution |
20 # of settings |
Microstep resolution |
200 … 51200 Range steps/rev |
Counter type |
Position 32-bit |
Counter edge rate |
5 MHz (max.) |
Velocity range |
± 2560000 | ± 3000 steps/sec | RPM |
Velocity resolution |
0.5961 steps/sec |
Accel/Decel range |
1.5 X 10^9 steps/sec2 |
Accel/Decel resolution |
90.9 steps/sec2 |
Encoder type |
Internal, magnetic |
Encoder resolution |
1000 / 4000 Lines / Edges |
Absolute encoder: data retention on internal power |
max. 30 days |
Absolute encoder: data retention on internal power with battery pack |
5 years |
Counter resolution |
32 bit |
hMTechnology OFF, encoder ON |
Position maintenance, find index, stall detect |
hMTechnology ON, encoder OFF |
Anti-stall, variable current control, torque mode |
MCode OS program storage |
Flash Type |
MCode OS program storage |
11.120 Bytes |
User registers |
4 Integer |
User registers |
8 Floating Point |
User registers |
32 Length [Bits] |
Math |
+, -, x, ÷, >, <, =, <=, >= |
Logic |
AND, OR, XOR, NOT |
Trigonometric |
ABS, COS, ACOS, LOG2, LOG10, PI, SIN, ASIN, SQRT, TAN, ATAN |
Branch functions |
Branch & call |
Input functions |
Home, limit plus, limit minus, go, stop, pause, jog plus, jog minus, general purpose, capture |
Output functions |
Moving, error, velocity change, stall, locked rotor, moving position, hMT active, make-up active, encoder A, encoder B, trip, attention. general purpose, |
Trip functions |
Trip on input, trip on position, trip on time, trip capture, trip on relative position, trip on main power loss |
Encoder functions1 |
hMTechnology, stall detection, position maintenance, find index |
EtherNet/IP (ODVA Confomance Checked) Object model |
Identity object 0x01 |
EtherNet/IP (ODVA Confomance Checked) Object model |
Assembly object (parameters mappable) 0x04 |
EtherNet/IP (ODVA Confomance Checked) Object model |
TCP object 0xF5 |
EtherNet/IP (ODVA Confomance Checked) Object model |
Ethernet object 0xF6 |
EtherNet/IP Manufacturer specific object classes |
Setup instructions 0x64 |
EtherNet/IP Manufacturer specific object classes |
Miscellaneous instructions and flags 0x65 |
EtherNet/IP Manufacturer specific object classes |
Motion instructions and flags 0x66 |
EtherNet/IP Manufacturer specific object classes |
I/O instruction variables and flags 0x67 |
EtherNet/IP Manufacturer specific object classes |
Position related instructions and flags 0x68 |
EtherNet/IP Manufacturer specific object classes |
Encoder related instructions and flags1 0x69 |
EtherNet/IP Manufacturer specific object classes |
hMTechnology specific instructions1 0x6A |
Modbus/TCP Device ID |
Read device identification 43/14d (0x2B/0x0E) |
Modbus/TCP Public function codes |
Read digital inputs 02d (0x02) |
Modbus/TCP Public function codes |
Read coils (digital outputs) 01d (0x01) |
Modbus/TCP Public function codes |
Write single coil (digital output) 05d (0x05) |
Modbus/TCP Public function codes |
Read holding register 03d (0x03) |
Modbus/TCP Public function codes |
Write multiple registers 16d (0x10) |
Modbus/TCP Manufacturer specific function codes |
Read I/O and trip configuration and parameters 65d (0x41) |
Modbus/TCP Manufacturer specific function codes |
Write I/O and trip configuration and parameters, enter upgrade mode. 66d (0x42) |
Modbus/TCP Profinet IO |
Slot 1 Output |
Modbus/TCP Profinet IO |
128 Bytes Size |
Modbus/TCP Profinet IO |
38 Registers |
Modbus/TCP Profinet IO |
Slot 2 Input |
Modbus/TCP Profinet IO |
34 Registers |
Modbus/TCP Profinet IO |
Variable, user defined Register mapping |