Produkt
incl. VAT
Flange dimensions: 100 mm
Rated Output Power: 820 – 1570 W
Rated Torque: 2,61 – 5,0 Nm
Rated Speed: 3000 rpm
incl. VAT
Flange dimensions: 100 mm
Rated Output Power: 820 – 1570 W
Rated Torque: 2,61 – 5,0 Nm
Rated Speed: 3000 rpm
Specification | TC-X 100 3,2 21 | TC-X 100 3,2 15 | TC-X 100 5,6 15 | TC-X 100 8 15 |
---|---|---|---|---|
Continous Stall Torque (ambient temperature 0 to +40°C) | 3.2 Nm | 3.2 Nm | 5.6 Nm | 8 Nm |
Peak Torque (ambient temperature 0 to +40°C) | 11 Nm | 11 Nm | 22 Nm | 33 Nm |
Nominal Torque (ambient temperature 0 to +40°C) | 2.61 Nm | 2.61 Nm | 4.2 Nm | 5 Nm |
Rated Voltage (ambient temperature 0 to +40°C) | 230 Vdc | 400 Vdc | 400 Vdc | 400 Vdc |
Nominal power (ambient temperature 0 to +40°C) | 820 W | 820 W | 1320 W | 1570 W |
Continuous stall Current (ambient temperature 0 to +40°C) | 6.08 Arms | 3.52 Arms | 6.15 Arms | 8.79 Arms |
Maximun Current (ambient temperature 0 to +40°C) | 20.91 Arms | 12.09 Arms | 24.18 Arms | 36.27 Arms |
Nominal Current (ambient temperature 0 to +40°C) | 5.121 Arms | 2.96 Arms | 4.76 Arms | 5.66 Arms |
Nominal working Speed (ambient temperature 0 to +40°C) | 3000 rpm | 3000 rpm | 3000 rpm | 3000 rpm |
Maximum working speed 230VAC (ambient temperature 0 to +40°C) | 5000 rpm | 3900 rpm | 3900 rpm | 3900 rpm |
Maximum working speed 400VAC (ambient temperature 0 to +40°C) | – | 5000 | 5000 | 5000 |
Torque Constant (ambient temperature 0 to +40°C) | 0.526 Nm/Arms | 0.91 Nm/Arms | 0.91 Nm/Arms | 0.91 Nm/Arms |
Voltage Constant (ambient temperature 0 to +40°C) | 31.8 Vrms/Krpm | 55 Vrms/Krpm | 55 Vrms/Krpm | 55 Vrms/Krpm |
Winding resistance (ambient temperature 0 to +40°C) | 1.1 Ω | 2.9 Ω | 1.17 Ω | 0.69 Ω |
Winding inductance (ambient temperature 0 to +40°C) | 4.44 mH | 13.28 mH | 6.33 mH | 4.22 mH |
Electrical time constant (ambient temperature 0 to +40°C) | 4.03 ms | 4.58 ms | 5.41 ms | 6.12 ms |
Thermal Resistance (ambient temperature 0 to +40°C) | 1 °C/W | 1 °C/W | 0.95 °C/W | 0.78 °C/W |
Mechanical time constant (ambient temperature 0 to +40°C) | 0.92 ms | 0.81 ms | 0.62 ms | 0.51 ms |
Rotor Inertia without feedback (ambient temperature 0 to +40°C) | 1.55 kg·cm² | 1.55 kg·cm² | 2.91 kg·cm² | 4.1 kg·cm² |
Mass (ambient temperature 0 to +40°C) | 3.9 Kg | 3.9 Kg | 5.6 Kg | 7.3 Kg |
Maximum axial shaft load applied on the shaft’s center (ambient temperature 0 to +40°C) | 225 N | 225 N | 225 N | 225 N |
Maximun radial shaft load applied on the shaft’s center (ambient temperature 0 to +40°C) | 626 N | 626 N | 626 N | 626 N |
Family Specification | Produkt |
---|---|
Time Rating | Continous |
Insulation Class | F |
Enclosure | Totally enclosed. Self-cooled |
Protection Class | IP 65 standard on the body |
Insulation System UL/CSA | cURus , DV155J File nr. : E216686 |
Ambient Temperature | -40 to 80 °C |
Ambient Humidity | 5 to 85% (non-condensing) |
Poles | 8 |
Thermal Protection | PT1000 |
Certification | CE |
Family Overview | Produkt |
---|---|
Flange dimensions | 100 mm |
Rated Output Power | 820 – 1570 Watt |
Rated Torque | 2,61 – 5,0 Nm |
Rated Speed | 3000 rpm |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
Specification | TC-X 100 3,2 21 |
---|---|
Continous Stall Torque (ambient temperature 0 to +40°C) | 3.2 Nm |
Peak Torque (ambient temperature 0 to +40°C) | 11 Nm |
Nominal Torque (ambient temperature 0 to +40°C) | 2.61 Nm |
Rated Voltage (ambient temperature 0 to +40°C) | 230 Vdc |
Nominal power (ambient temperature 0 to +40°C) | 820 W |
Continuous stall Current (ambient temperature 0 to +40°C) | 6.08 Arms |
Maximun Current (ambient temperature 0 to +40°C) | 20.91 Arms |
Nominal Current (ambient temperature 0 to +40°C) | 5.121 Arms |
Nominal working Speed (ambient temperature 0 to +40°C) | 3000 rpm |
Maximum working speed 230VAC (ambient temperature 0 to +40°C) | 5000 rpm |
Maximum working speed 400VAC (ambient temperature 0 to +40°C) | – |
Torque Constant (ambient temperature 0 to +40°C) | 0.526 Nm/Arms |
Voltage Constant (ambient temperature 0 to +40°C) | 31.8 Vrms/Krpm |
Winding resistance (ambient temperature 0 to +40°C) | 1.1 Ω |
Winding inductance (ambient temperature 0 to +40°C) | 4.44 mH |
Electrical time constant (ambient temperature 0 to +40°C) | 4.03 ms |
Thermal Resistance (ambient temperature 0 to +40°C) | 1 °C/W |
Mechanical time constant (ambient temperature 0 to +40°C) | 0.92 ms |
Rotor Inertia without feedback (ambient temperature 0 to +40°C) | 1.55 kg·cm² |
Mass (ambient temperature 0 to +40°C) | 3.9 Kg |
Maximum axial shaft load applied on the shaft’s center (ambient temperature 0 to +40°C) | 225 N |
Maximun radial shaft load applied on the shaft’s center (ambient temperature 0 to +40°C) | 626 N |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
Specification | TC-X 100 3,2 15 |
---|---|
Continous Stall Torque (ambient temperature 0 to +40°C) | 3.2 Nm |
Peak Torque (ambient temperature 0 to +40°C) | 11 Nm |
Nominal Torque (ambient temperature 0 to +40°C) | 2.61 Nm |
Rated Voltage (ambient temperature 0 to +40°C) | 400 Vdc |
Nominal power (ambient temperature 0 to +40°C) | 820 W |
Continuous stall Current (ambient temperature 0 to +40°C) | 3.52 Arms |
Maximun Current (ambient temperature 0 to +40°C) | 12.09 Arms |
Nominal Current (ambient temperature 0 to +40°C) | 2.96 Arms |
Nominal working Speed (ambient temperature 0 to +40°C) | 3000 rpm |
Maximum working speed 230VAC (ambient temperature 0 to +40°C) | 3900 rpm |
Maximum working speed 400VAC (ambient temperature 0 to +40°C) | 5000 |
Torque Constant (ambient temperature 0 to +40°C) | 0.91 Nm/Arms |
Voltage Constant (ambient temperature 0 to +40°C) | 55 Vrms/Krpm |
Winding resistance (ambient temperature 0 to +40°C) | 2.9 Ω |
Winding inductance (ambient temperature 0 to +40°C) | 13.28 mH |
Electrical time constant (ambient temperature 0 to +40°C) | 4.58 ms |
Thermal Resistance (ambient temperature 0 to +40°C) | 1 °C/W |
Mechanical time constant (ambient temperature 0 to +40°C) | 0.81 ms |
Rotor Inertia without feedback (ambient temperature 0 to +40°C) | 1.55 kg·cm² |
Mass (ambient temperature 0 to +40°C) | 3.9 Kg |
Maximum axial shaft load applied on the shaft’s center (ambient temperature 0 to +40°C) | 225 N |
Maximun radial shaft load applied on the shaft’s center (ambient temperature 0 to +40°C) | 626 N |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
Specification | TC-X 100 5,6 15 |
---|---|
Continous Stall Torque (ambient temperature 0 to +40°C) | 5.6 Nm |
Peak Torque (ambient temperature 0 to +40°C) | 22 Nm |
Nominal Torque (ambient temperature 0 to +40°C) | 4.2 Nm |
Rated Voltage (ambient temperature 0 to +40°C) | 400 Vdc |
Nominal power (ambient temperature 0 to +40°C) | 1320 W |
Continuous stall Current (ambient temperature 0 to +40°C) | 6.15 Arms |
Maximun Current (ambient temperature 0 to +40°C) | 24.18 Arms |
Nominal Current (ambient temperature 0 to +40°C) | 4.76 Arms |
Nominal working Speed (ambient temperature 0 to +40°C) | 3000 rpm |
Maximum working speed 230VAC (ambient temperature 0 to +40°C) | 3900 rpm |
Maximum working speed 400VAC (ambient temperature 0 to +40°C) | 5000 |
Torque Constant (ambient temperature 0 to +40°C) | 0.91 Nm/Arms |
Voltage Constant (ambient temperature 0 to +40°C) | 55 Vrms/Krpm |
Winding resistance (ambient temperature 0 to +40°C) | 1.17 Ω |
Winding inductance (ambient temperature 0 to +40°C) | 6.33 mH |
Electrical time constant (ambient temperature 0 to +40°C) | 5.41 ms |
Thermal Resistance (ambient temperature 0 to +40°C) | 0.95 °C/W |
Mechanical time constant (ambient temperature 0 to +40°C) | 0.62 ms |
Rotor Inertia without feedback (ambient temperature 0 to +40°C) | 2.91 kg·cm² |
Mass (ambient temperature 0 to +40°C) | 5.6 Kg |
Maximum axial shaft load applied on the shaft’s center (ambient temperature 0 to +40°C) | 225 N |
Maximun radial shaft load applied on the shaft’s center (ambient temperature 0 to +40°C) | 626 N |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.
Specification | TC-X 100 8 15 |
---|---|
Continous Stall Torque (ambient temperature 0 to +40°C) | 8 Nm |
Peak Torque (ambient temperature 0 to +40°C) | 33 Nm |
Nominal Torque (ambient temperature 0 to +40°C) | 5 Nm |
Rated Voltage (ambient temperature 0 to +40°C) | 400 Vdc |
Nominal power (ambient temperature 0 to +40°C) | 1570 W |
Continuous stall Current (ambient temperature 0 to +40°C) | 8.79 Arms |
Maximun Current (ambient temperature 0 to +40°C) | 36.27 Arms |
Nominal Current (ambient temperature 0 to +40°C) | 5.66 Arms |
Nominal working Speed (ambient temperature 0 to +40°C) | 3000 rpm |
Maximum working speed 230VAC (ambient temperature 0 to +40°C) | 3900 rpm |
Maximum working speed 400VAC (ambient temperature 0 to +40°C) | 5000 |
Torque Constant (ambient temperature 0 to +40°C) | 0.91 Nm/Arms |
Voltage Constant (ambient temperature 0 to +40°C) | 55 Vrms/Krpm |
Winding resistance (ambient temperature 0 to +40°C) | 0.69 Ω |
Winding inductance (ambient temperature 0 to +40°C) | 4.22 mH |
Electrical time constant (ambient temperature 0 to +40°C) | 6.12 ms |
Thermal Resistance (ambient temperature 0 to +40°C) | 0.78 °C/W |
Mechanical time constant (ambient temperature 0 to +40°C) | 0.51 ms |
Rotor Inertia without feedback (ambient temperature 0 to +40°C) | 4.1 kg·cm² |
Mass (ambient temperature 0 to +40°C) | 7.3 Kg |
Maximum axial shaft load applied on the shaft’s center (ambient temperature 0 to +40°C) | 225 N |
Maximun radial shaft load applied on the shaft’s center (ambient temperature 0 to +40°C) | 626 N |
Technical specifications are for guidance only, as the individual drives and motors are configured for specific applications. Subject to technical and visual changes.